    Distributed Optical Fiber Inspection for Direct Buried Thermal Insulation Pipeline
    0
    Publisher: admin  Publishing time: 2019-04-10 Hits: 900 times
    Central heating has become the main way to solve the problem of heating in medium, large and super-large cities in China. Compared with foreign countries, although the development of central heating in China is relatively late, it has developed rapidly in recent years, and has the characteristics of large pipe diameter and long transmission distance. At present, the laying mode...

    Central heating has become the main way to solve the problem of heating in medium, large and super-large cities in China. Compared with foreign countries, although the development of central heating in China is relatively late, it has developed rapidly in recent years, and has the characteristics of large pipe diameter and long transmission distance. At present, the laying mode of thermal insulation pipeline network in China is mainly directly buried. However, due to the interaction of material aging, environmental corrosion, extreme load and other conditions, the structural state degradation of directly buried heating pipeline is inevitable, and even the safety accident of pipeline leakage occurs. Pipeline leakage not only causes huge direct and indirect economic losses, but also has a serious impact on people's lives and public safety. Therefore, the safety monitoring, evalsuation and early warning technology of directly buried thermal insulation pipeline has become the focus of research.
    The primary stress is the main factor affecting the structural safety of directly buried heating and insulation pipelines, while the bending stress caused by overlying soil load and uneven settlement is the main form of primary stress. At present, there is no effective method to monitor the primary stress of directly buried heating pipelines.
    In view of the difficulty in quantifying the bending strain of the working pipe of the directly buried thermal insulation pipeline in practical engineering, a method for monitoring the structural state of the heating pipeline based on distributed optical fiber sensor is proposed. The monitoring system includes sensor unit, data acquisition unit and remote data transmission unit. Distributed fiber optic strain sensor and distributed fiber optic temperature sensor are arranged between insulation layer and outer protective tube to realize remote real-time monitoring of bending strain and leakage behavior of working tube. The monitoring of a directly buried heating pipe section under backfilling construction is carried out.
    Distributed optical fiber temperature sensor can truly measure the temperature distribution along the pipeline. Distributed optical fiber strain sensor can effectively monitor the bending strain of the working pipe. Monitoring data show that the bending stress of insulating pipes caused by overlying soil load, uneven groove foundation and uneven settlement is very significant. As a primary stress, it is very important for the safety of pipelines. Ignoring the primary stress related to bending behavior in the safety assessment of heating pipes will lead to unsafe results. It is necessary to implement distributed real-time monitoring for directly buried thermal insulation pipelines.

    Survey & dynamic
    Company Profile
    Corporate Culture
    Honor Certificate
    Company News
    Industry Dynamics
     
    Product Display
    Polyurethane Thermal Insulation Pipe
    Steel Casing Steel Steam Pipe
    PE Outer Sheath
    Thermal Insulation Pipe Fittings
    Engineering & Technology
    Case Show
    Project Performance
    Production Equipment
    Test Equipment
    Contact Information
    Copyright 2019 All Rights Reseved 
    Hebei Baoli Thermal Pipeline Engineering Co., Ltd.
    Monday to Sunday 07:00 - 20:00
    400-0316-266
    網站地圖蜜柚下载官网 葡萄视频在线观看 91葡萄视频污 樱桃视频影院在线播放免费下载 蘑菇视频在线下载官网免费 香蕉黄片免费看 蜜桃污污污网站 蘑菇视频版下载官网 水蜜桃视频污在线观看 茄子视频免费观看