    Environmental Characteristics of Gas and Thermal Insulation Pipeline System Gallery in Service
    0
    Publisher: admin  Publishing time: 2019-04-21 Hits: 1219 times
    The general characteristics of the comprehensive pipeline gallery system are embodied in the following environmental characteristics of the service gallery of the gas and heat preservation pipeline system (hereinafter referred to as the dangerous pipeline).(1) Hazardous sensitive pipes are installed in separate compartments (gas and steam pipes are laid in a single compartment,...

    The general characteristics of the comprehensive pipeline gallery system are embodied in the following environmental characteristics of the service gallery of the gas and heat preservation pipeline system (hereinafter referred to as the dangerous pipeline).
    (1) Hazardous sensitive pipes are installed in separate compartments (gas and steam pipes are laid in a single compartment, high temperature pipes can be shared with some pipes), piping corridors are laid to avoid damage by third parties in the external environment, and anti-intrusion monitoring system is installed at the entrance and exit of the piping corridor, which can monitor the situation of personnel entering the piping corridor in real time.
    (2) When laying dangerous sensitive pipelines in the corridor, maintenance channels should be considered in the design of the cabin so as to facilitate the daily management and maintenance of professionals and avoid the passivity of post-discovery and post-treatment of leakage accidents of buried dangerous sensitive pipelines.
    (3) The dangerous pipeline in the corridor is laid by bracket, which avoids electrochemical corrosion of soil electrolyte, sulfate reducing bacteria corrosion, interaction of pipeline and soil with external loads. The environmental temperature and humidity of pipeline laying are relatively stable, and the service period of pipeline is long.
    (4) The leakage of dangerous media can be detected in time and alarmed for disposal. The accident fan can be opened in chain, and the dangerous pipeline valves inside and outside the gallery can be shut down remotely according to the need.
    (5) Once the gas and heat preservation pipeline transmission medium leaks to the pipeline gallery, it can only be discharged through the exhaust outlet, which requires relatively high leakage monitoring, chain automatic control system and ventilation system.

    Survey & dynamic
    Company Profile
    Corporate Culture
    Honor Certificate
    Company News
    Industry Dynamics
     
    Product Display
    Polyurethane Thermal Insulation Pipe
    Steel Casing Steel Steam Pipe
    PE Outer Sheath
    Thermal Insulation Pipe Fittings
    Engineering & Technology
    Case Show
    Project Performance
    Production Equipment
    Test Equipment
    Contact Information
    Copyright 2019 All Rights Reseved 
    Hebei Baoli Thermal Pipeline Engineering Co., Ltd.
    Monday to Sunday 07:00 - 20:00
    400-0316-266
    網站地圖蜜柚下载官网 葡萄视频在线观看 91葡萄视频污 樱桃视频影院在线播放免费下载 蘑菇视频在线下载官网免费 香蕉黄片免费看 蜜桃污污污网站 蘑菇视频版下载官网 水蜜桃视频污在线观看 茄子视频免费观看